EXES-6000 CP-64INTERCOM SYSTEMCP-64Functions andOperating InstructionsTOA ELECTRIC CO., LTD.KOBE, JAPAN133-06-081-8

Page 2 - Contents

3) Hands-free Master StationModel HF-620M/630M/631M/650MNP TypeSpeaker volume switchMicrophoneSpeakerIn-use lampPrivacy switchDial keyskeyHF-620MH

Page 3 - Privacy

Note.When 2 or 3 exchanges are connected by tie-lines, DataTransmitting and Receiving Units can be operated fromthe stations which share

Page 4

Simplified PagingIf an external speaker is connected instead of a station,simplified paging can be made without the PA amplifier if

Page 5 - Chapter 1

TOA ELECTRIC CO, LTD.KOBE,JAPANPrinted in Japan

Page 6 - Stations

4) Hands-free SubstationModel (HF-620S/630S/631S/640S) PV TypeSpeaker volume switchMicrophoneSpeake

Page 7 - Speech functions

4) Hands-free SubstationModel (HF-620S/630S/631S/640S)NP TypeSpeaker volume switchMicrophoneSpeakerIn-use lampPrivacy switchDial keyskeyHF-620SHF-6

Page 8

5) Hands-free / Handset Master StationModel HF-600M/610M/660M (With Auto-Dialer) PV TypeHandsetSpeaker volume switchMicrophon

Page 9

5) Hands-free / Handset Master StationModel HF-600M/610M/660M (With Auto-Dialer) NP TypeHandsetSpeaker volume switchMic

Page 10 - NP Type

6) Hands-free / Handset SubstationModel HF-600S/610 PV TypeHandsetSpeaker volume switchMicrop

Page 11 - 4) Hands-free Substation

6) Hands-free / Handset substationModel HF-600S/610SNP TypeHandsetSpeaker volume switchMicrophoneLoud speakerSpeakerIn-use lampPrivacy switchDial ke

Page 12 - Dial keys

7) Hands-free / Handset Master Station with Auto-DialerModel HF-660 PV TypeNP TypeHandsetRegistration mode switchPrivacy/In-use lampPri

Page 13 - PV Type

Functions: EXES-6000 CP-64No.ClassificationAutomatic Line ReleaseCamp-On-BusyMic-OffSingle Digit DialingAutomatic Access to PagingMaster/Sub Rela

Page 14 - Microphone

Functions: EXES-6000 CP-64Notes.1. XX/YY indicates to select either XX (Function) orYY (Function).2. Not all circles ( ) in The Switc

Page 15 - < Making a call >

Introduction to the "Functions and Operatinglnstructions" for stations for EXES-6000 ... 3Chapter 1. Basic Functions, Their Operat

Page 16 - In-use lamp

Chapter 2Functions and operating proceduresof single exchange system fora maximum of 256 stations

Page 17 - Registration mode switch

Volume switchAdjusts the volume of the stationspeaker.In-use LampLights up when the station is online with another station.Pocket PagerresponseConfe

Page 18 - Functions: EXES-6000 CP-64

Besides fixed standard functions, there are selectablestandard functions and optional functions.Selectable standard functions can be select

Page 19 - (without zone No.)

3. Optional Functions27) Station Paging and Response (PI-62 Unit is required)Paging is available through the built-in stationspeakers. Pa

Page 20 - Chapter 2

ClassificationCallFunctionPress-to-talkRemote responseRemote response registrationContinuous calling tone responsePrivacySecretary transferSingle digi

Page 21

ClassificationPagingFunctionAll-call plus9-zone pagingAll-call plus 31-zone pagingCombination pagingAl I -call responseZone paging responsePaging tra

Page 22 - Function description

Automatic Line ReleaseWhen, in dialing, all of the numbers are not dialed within5 seconds, the station is automatically disconnected f

Page 23 - 3. Optional Functions

Camp-On PrivacyPV TypeWhen the party you are calling has his station on Privacymode, by simply waiting you will automatically "C

Page 24 - 9 and the

Press-To-Talk ControlTouch dialing the specific station number.One way conversation is activated while the Press-To-Talkbar is continuously d

Page 25 - Description

Single Digit DialingSingle digit registrationRegister in advance as follows:Confirmation toneStation numberConfirmation tonePersonal numberConfirma

Page 26 - After call

Chapter 3. Functions and Operating Procedures of Tie-LineSystem for a Maximum of 768 Stations1. Part Names and Functions of the Station Keyboard

Page 27 - 10 seconds

Master Sub RelationshipMaster/Substation associations are set up by using station#200 as the programming station. Once these relationshipshave b

Page 28 - The relay of PI-62 unit

Personal Number CallA personal number may be registered at any master stationwhich the person to whom the number is assigned expectsto

Page 29 - Single digit

Continuous Calling ToneWhen a specified station receives a call, the calling tonecontinues untilis depressed by this party.1. When calls c

Page 30 - Automatic Access To Paging

Remote ResponseThis feature is available only among stations programmedfor this purpose. When a station at which no one is presentis calle

Page 31 - Personal Number Call

Call TransferCall Transfer from Called StationCallDuring the conversation, first dial(the Station Number of the person the call is to be tr

Page 32 - Continuous Calling Tone

Paging during Normal CallsA paging call can be made by a called party of an existingcall to a third party, the third party'

Page 33 - Remote Response

Secretary TransferThis function is only available when a specified station isprogrammed for this purpose with use of Station #200 inthe pro

Page 34 - Called Station

Secretary Transfer and Call TransferPV TypeAdoption of the selective function "Transfer" allows rerout-ing of the call transferred to

Page 35 - Station paging

Secretary Transfer end Cell TransferAdoption of the selective function "Transfer" allows rerout-ing of the call transferred to the se

Page 36 - Executive

Call ForwardingWhen you will be away from your station and wish allincoming calls to be rerouted to a different destination youare going

Page 37

This handbook explains the functions and operatingprocedures of stations for TOA's EXES-6000 IntercomSystem using central processi

Page 38 - Touch dial

PriorityWhen the party called is on the line, as indicated by thebusy tone, dialingtransmits a priority tone to the called party. Th

Page 39 - Original Station No

Highest Executive PriorityThis function is available only for those stations specificallyprogrammed for this function, with programming stationN

Page 40 - Holding Tone

ConferenceA "Hands-Free" conference call can be made with up to4 persons. For a conference under this function the otherparticip

Page 41 - Conversation Over

PagingA variety of paging modes allows paging over a wide areafrom any master station. The paged party may respondfrom the nearest

Page 42 - Conference

Other Paging Modes1. Combination pagingCombination paging is used when several zones must bepaged simultaneously through External PA or

Page 43 - B. All-call paging

How to select the paging area and make the paging call.Paging functions may include both external PA and sta-tions, depending on the zone

Page 44 - Other Paging Modes

All-Call Paging and Individual Zone PagingPaging callExternal PA paging to a specific zone is possible from anymaster station by pressing(&ap

Page 45 - Combination

Combination PagingSeveral zones can be called simultaneously using externalPA paging and station paging. This is combination pagingand

Page 46 - All-call paging

< Example 4 >To operate combination paging. No. 200 registration indi-cating the individual zones to be included in the combina-

Page 47 - Combination Paging

Emergency All-Call PagingHandset substation TL-600S should normally be used forthe emergency all-call station, No. 247.< Emergency all

Page 48 - < Example 4 >

Chapter 1Basic functions, their operatingprocedures and all functions

Page 49 - All-call

Paging PriorityWhen using the standard paging functions, paging is notheard while other calls are in progress.< Example 1 >*: Conver

Page 50 - Paging Priority

Personal Number PagingIf you wish to receive personal number paging calls, youmay register your personal number at any station assi

Page 51 - Cancelling Personal number

Selectable First Station NumberThe first station number for system may be selectedfrom any of the following numbers (Hardwiredstation numbe

Page 52 - (Hardwired station

Group BlockingNote.1. When the paging call is made, the group of stations towhich the response is made is restricted by FunctionB. Functi

Page 53 - < Example >

Programmable Restricted Access for StationsStations which can use the 6 groups of following functionsmust be programmed, so as to restrict

Page 54 - 000 ~ 511

Selectable Calling ToneThe duration of the calling tone can be set for either 0.2second (single note tone) or 0.3 second (warble t

Page 55 - Time-Out of Paging Call

In/Out AnnunciationThe in/out annunciation indicators can be turned on oroff from any master station by using the personal numberregis

Page 56 - 1000~1999 (personal number)

Destination Annunciation IndicationWhen a personal number is registered at the station of thedestination a person has moved to, the cor

Page 57 - At any station

Calling Party Indication (Lamp Type)A one station/one lamp type calling party indication panelcan be provided for certain specified station

Page 58 - Last station

< Calling party selection >1. When there are more than 2 incoming calls to a busystation, the calling parties' lamps on t

Page 59 - Waiting station

1. TL-600M2. TL-600S3. HF-660M4. AK-0245. HF-600M6. HF-600S7. HF-610M8. HF-610SDesk/Wall-Mounted Handset MasterStationDesk/Wall-Mounted Han

Page 60 - (00 ~ 99, Pager No.)

Pocket PagerThe system can be connected with usual type Pocket pagerusing the interface with Make/break relay output.1. Dial(00 ~ 99, Pager No.

Page 61 - General Purpose Control

General Purpose ControlStation may be restricted from access to this function. Thisfunction can control other equipments by employing theD

Page 62

Simplified PagingIf an external speaker is connected instead of a station,simplified paging can be made without the PA amplifier if

Page 63 - Chapter 3

Chapter 3Functions and operating proceduresof tie-line system for a maximumof 768 stations

Page 64

Part names and functions of the station keyboardVolume switchAdjusts the volume of the stationspeaker.Pocket PagerresponseConferencePocket Pager c

Page 65 - (EX-2A) (EX-2B)

Tie-line Connections of Exchanges1. Purpose of tie-line connectionWhen the EXES-6000 system uses the Central ProcessingUnit Model CP-64, not

Page 66 - ~ 655 *1

3. Numbering schedule for stations and paging zonesType of exchangeSingle Exchange (EX-1)Exchange "A" (EX-2A/3A)Exchange "B&qu

Page 67

Function descriptionBesides fixed standard functions, there are selectablestandard functions and optional functions.Selectable standard funct

Page 68

21) Group HuntingWhen the first called party in a group is busy, the callis automatically transferred to the next stations.22) Secretary TransferC

Page 69

Restrictions Resulting from Tie-line ConnectionTie-line1. Paging1) Paging is possible up to a maximum number of 15zone per exchange.2)

Page 70

Either "PV" Type (the system with Privacy function) or "NP" Type (Without Privacy function) mode should be selected i

Page 71 - 67 -

EXES-6000, CP-64 Summary of Dial OperationsTie-line system of 2 or 3 exchangesStation numbering: No. 200 ~ 455, No. 470 ~ 725, No. 740

Page 72 - One tone

ClassificationPagingDisplayandControlDataTransmittingandReceivingUnitFunction<Tie-line system of 2 exchanges>All-call plus 30-zone paging<Tie

Page 73 - Camp-On Privacy

Automatic Line ReleaseWhen, in dialing, all of the numbers are not dialed within5 seconds, the station is automatically disconnected fr

Page 74

Camp-On PrivacyWhen the party you are calling has his station on Privacymode, by simply waiting you will automatically "Camp-On&q

Page 75 - Automatic Access To Paging

Single Digit DialingSingle digit registrationRegister in advance as follows:Confirmation toneStation numberConfirmation tonePersonal numberConfirmat

Page 76

Master Sub RelationshipMaster/Substation associations are set up by using station#200 as the programming station. Once these relationshipshave b

Page 77

Personal Number CallTie-lineA personal number may be registered at any master stationwhich the person to whom the number is assigned e

Page 78

Continuous Calling ToneWhen a specified station receives a call, the calling tonecontinues until(except key)is depressed by this party.1.

Page 79

Remote ResponseThis feature is available only among stations programmedfor this purpose. When a station at which no one is presentis called

Page 80 - Group Hunting

Call TransferTie-lineCall Transfer from Called StationDuring the conversation, first dial(the Station Number of the person the call is to

Page 81 - Secretary Transfer

1) Handset Master StationModel TL-600MNP TypeHandsetIn-use lampSpeaker volume switchDial keyskey< Making a call >1. Pick up the han

Page 82

A paging call can be made by a called party of an existingcall to a third party, the third party's response acceptedwhile t

Page 83

This function is only available when a specified station isprogrammed for this purpose with use of Station #200 inthe programming mode. Auto

Page 84 - Highest Executive Priority

Adoption of the selective function "Transfer" allows rerout-ing of the call transferred to the secretary back to theexecutive&apos

Page 85 - Single Digit

Adoption of the selective function "Transfer" allows rerout-ing of the call transferred to the secretary back to theexecutive&apos

Page 86

This function is available only for those stations specificallyprogrammed for this function, with programming stationNo. 200. When the stat

Page 87

A "Hands-Free" conference call can be made with up to4 persons. For a conference under this function the otherparticipants may

Page 88 - Zone No. 01 ~ 45

A variety of paging modes allows paging over a wide areafrom any master station. The paged party may respondfrom the nearest master

Page 89

Paging areaAll-call paging over theentire zones of exchanges"A", "B"and "C"*1Zone paging to the zoneof exchange

Page 90 - <Fig. 1>

External PA paging to a specific zone is possible from anymaster station by pressing after picking up a handsetIt is possible to wait

Page 91

1.. The exchanges A, B and C permit the following StandardStation Numbering Schedules (Hardwired stationnumber):< Standard station numberin

Page 92 - Paging to Zone No. 31

3) Hands-free Master StationModel HF-620M/630M/631M/650MPV TypeSpeaker volume switchMicrophoneSpeakerIn-use lampPrivacy switchDial keyskeyHF-620M

Page 93

Programmable Station Numbering1. Numbering schedules can be changed easily by pro-gramming in stead of rewiring.2. Numbering schedule (su

Page 94 - Selectable Calling Tone

Group BlockingFunction (A)The system can be grouped or divided into a maximumof 6 groups of stations with consecutive station numbersby excha

Page 95

Example of Group Blocking registrationTo use this function, station No. 200 programming (No.470programming or No.740 programming) of the alloca

Page 96

Programmable Restricted Access for StationsTie-lineStations which can use the 6 groups of following functionsmust be programmed, so as to r

Page 97 - "Call Back".)

Selectable Calling ToneTie-lineThe duration of the calling tone can be set for either 0.2second (single note tone) or 0.3 second (

Page 98 - Response

The in/out annunciation indicators can be turned on oroff from any master station by using the personal numberregistering procedure.W

Page 99 - Example: VTR control

Calling Party Indication (Lamp Type)Tie-lineA one station/one lamp type calling party indication panelcan be provided for certain specified

Page 100 - Tie-line

< Calling party selection >1. When there are more than 2 incoming calls to a busystation, the calling parties' lamps on

Page 101 - Simplified Paging

Pocket PagerTie-lineThe system can be connected with usual type Pocket pagerusing the interface with Make/break relay output.1. Dial(00 ~ 99, P

Page 102 - TOA ELECTRIC CO, LTD

General Purpose ControlTie-lineStation may be restricted from access to this function. Thisfunction can control other equipments by employi